×
Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Overhead Neutral-supported Multiplex Conductor:Cockle

Code Word: Cockle

Size AWG (Phase Conductors): 2

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


2-2-4 Cockle Aluminum Conductor Overhead Service Drop Cable Wire has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.


2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



 
TECHNICAL DATA :

2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
 2-2-4 Cockle Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter 
 
Code Name Cockle
Phase Conductor Size/AWG 2
Phase Conductor Stranding 7/W
Phase Conductor Insulation Thickness 45 mls
Bare Neutral Messenger Size/AWG 4
Bare Neutral Messenger Stranding 6/1
Bare Neutral Messenger Breaking Strength 1860 Lbs
Weight Per (lb/1000 ft) XLP 233 Lbs
Weight (lb/1000 ft) Poly 227 Lbs
Ampacity XLP 150 Amps
Ampacity Poly 120 Amps
Send message
SEND
RESET
Related products