3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Overhead Neutral-supported Multiplex Conductor:Aega

Code Word: Aega

Size AWG (Phase Conductors): 3/0

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire has three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.


3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts 
CONSTRUCTION :

3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger)Conductor

Bare ACSR messenger. 

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
TECHNICAL DATA :

3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
3/0-3/0-1/0 Aega Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter
Code Name Aega
Phase Conductor Size/AWG 3/0
Phase Conductor Stranding 19/w
Phase Conductor Insulation Thickness 60 mls
Bare Neutral Messenger Size/AWG 1/0
Bare Neutral Messenger Stranding 6/1
Bare Neutral Messenger Breaking Strength 4380 Lbs
Weight Per (lb/1000 ft) XLP 565 Lbs
Weight (lb/1000 ft) Poly 552 Lbs
Ampacity XLP 275 Amps
Ampacity Poly 215 Amps