4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Overhead Neutral-supported Multiplex Conductor:Arca

Code Word: Arca

Size AWG (Phase Conductors): 4/0

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


4/0-4/0-2/0 Arca Aluminum Conductor Overhead Service Drop Cable Wirehas three conductors, with one of them being for neutral path, and two electrodes. The aluminum triplex cable is an electrical cable meant for power distributions from the utility lines to the consumer’s premises through the weather head. It has an operational voltage rating at 600 V and the maximum temperature rating of 75°C. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.



4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

 4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger. 

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
 
TECHNICAL DATA :

4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
4/0-4/0-2/0 Arca Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter
Code Name Arca
Phase Conductor Size/AWG 4/0
Phase Conductor Stranding 19/w
Phase Conductor Insulation Thickness 60 mls
Bare Neutral Messenger Size/AWG 2/0
Bare Neutral Messenger Stranding 7
Bare Neutral Messenger Breaking Strength 5390 Lbs
Weight Per (lb/1000 ft) XLP 671.2 Lbs
Weight (lb/1000 ft) Poly 644.6 Lbs
Ampacity XLP 315 Amps
Ampacity Poly 245 Amps