1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable

Overhead Neutral-supported Multiplex Conductor:Bull

Code Word: Bull

Size AWG (Phase Conductors): 1/0

Voltage: 600V

Number of cores: 2 cores

Package: Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable Application


1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable is designed for use to supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 90°C maximum.

Also Known As:
1/0-1/0 bull aluminium overhead cables, 1/0-1/0 bull overhead aluminum wire, 1/0-1/0 bull two conductor cable, 1/0-1/0 bull 2 conductor power cable, 1/0-1/0 bull two conductor, 1/0-1/0 bull aluminum drop, 1/0-1/0 bull overhead service drop conductors, 1/0-1/0 bull overhead service conductors.


1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable Construction
6-6 Shepherd Aluminum Conductor Duplex Overhead Service Drop Cable

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. .

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
 
TECHNICAL DATA :

1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
1/0-1/0 Bull Aluminum Conductor Duplex Overhead Service Drop Cable Parameter
Size AWG: 1/0
Stranding: 19/w
Insulation Thickness (mils): 0.060
Neutral Size AWG: 1/0
Weight lbs./1000ft: XLP: 289
Weight lbs./1000ft: Poly: 280
Ampacity: XLP: 205
Ampacity: Poly: 160 