Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
120mm2 Single Core 0.6/1KV Aluminium Wire Armoured AWA Cable

120mm2 Single Core armoured cable XLPE/PVC/AWA/PVC IEC 60502-1 0.6/1kV

Rated Voltage: 600/1000 Volts,

Conductor: Copper or Aluminum

Insulation: Cross Linked Poly Ethylene (XLPE)

Armour: Aluminum Wire Armour

Oversheath: PVC or LSZH

Email: manager@hdcable.com.cn

120mm2 Single Core 0.6/1KV Aluminium Wire Armoured AWA Cable

Single core PVC cable with aluminium wire armour (AWA).Power and auxiliary fixed wiring cables for use in powernetworks, underground, outdoor and indoor applications andfor use in cable ducting.

STANDARDS

BS 5467, IEC/EN 60502-1, IEC/EN 60228 , Flame Retardant according to IEC/EN 60332-1-2 
CONSTRUCTION :


 

Conductors: Plain circular, compacted or shaped stranded copper or aluminium conductor (Conductor shaped: RE=circular solid, CC=compacted circular stranded, SM=sector shaped stranded)
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Color identification 
1 Core : Red or Black,  2 Cores : Red, Black,  3 Cores: Red, Yellow, Blue , 4 Cores: Red, Yellow, Blue, Black,  5 Cores: Red, Yellow, Blue, Black, Green
Above 5 Cores: Black Cores with White numerals 
*The above identifying can be changed as user requirement
Assembly /Inner Sheath:Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted
Armour: Aluminum/Galvanized Steel Wires, single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.
Sheath:Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.
Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSZH, and CPE are available on request.

Fire Performance of Cable Sheaths

Cables can be supplied with special flame retardant PVC outer sheath to comply With the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, we can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards. 
DIMENSIONS :

120mm2 Single Core 0.6/1KV Aluminium Wire Armoured AWA Cable

Specification

Outer diameter of conductor

Nominal thickness of insulation

Diameter of

aluminium wire

Nominal sheath thickness

Approx.outer diameter of cable

Approx. Weight of cable

 Ampacity of cable

 Air

Soil

CU

AL

Cu

Al

Cu

Al

mm2

mm

mm

mm

mm

mm

kg/km

kg/km

A

A

A

A

1×4 RE

2.24

0.7

1.25

1.8

16.9

228

204

45

35

60

50

1×6 RE

2.76

0.7

1.25

1.8

16.9

258

222

55

45

70

50

1×10 CC

3.8

0.7

1.25

1.8

16.9

321

261

75

60

95

75

1×16 CC

4.8

0.7

1.25

1.8

17.0

357

255

100

80

125

100

1×25 CC

6.0

0.9

1.25

1.8

17.4

482

323

140

115

160

130

1×35 CC

7.0

0.9

1.25

1.8

18.4

597

375

175

140

190

150

1×50 CC

8.4

1.0

1.6

1.8

19.6

788

487

210

170

225

180

1×70 CC

10.0

1.1

1.6

1.8

21.5

1032

598

270

215

280

225

1×95 CC

11.5

1.1

1.6

1.8

23.1

1319

718

340

275

335

270

1×120 CC

13.0

1.2

2.0

1.8

24.7

1657

892

400

320

380

305

1×150 CC

14.5

1.4

2.0

1.8

26.7

1960

1048

460

370

425

340

1×185 CC

16.2

1.6

2.0

1.8

28.8

2375

1205

530

415

480

375

1×240 CC

18.4

1.7

2.0

1.8

31.6

3004

1467

625

490

555

435

1×300 CC

20.5

1.8

2.0

1.9

34.2

3655

1722

720

565

630

495

1×400 CC

23.5

2.0

2.5

2.0

39.3

4725

2245

815

640

705

555

1×500 CC

26.5

2.2

2.5

2.2

44.3

5837

2686

855

680

765

595

1×630 CC

30.0

2.4

2.5

2.3

50.4

7326

3271

980

790

860

680

 
TECHNICAL DATA :

120mm2 Single Core 0.6/1KV Aluminium Wire Armoured AWA Cable

Max. Permissible D.C. resistance of conductor at 20℃

Nominal section area(mm2) 

Copper conductor(Ω/km)

Aluminum conductor(Ω/km)

1.5

12.1

-

2.5

7.41

12.1

4

4.61

7.41

6

3.08

4.61

10

1.83

3.08

16

1.15

1.91

25

0.727

1.20

35

0.524

0.868

50

0.387

0.641

70

0.268

0.443

95

0.193

0.320

120

0.153

0.253

150

0.124

0.206

185

0.0991

0.164

240

0.0754

0.125

300

0.0601

0.100

400

0.0470

0.0778

500

0.0366

0.0605

630

0.0283

0.0469

 
Send message
SEND
RESET
Related products