Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
Your position: 
1.5mm 2.5mm 12 Core Steel Wire Armoured SWA Cable

PVC Insulated, PVC Sheathed Armoured 12 Core Control Cable 0.6/1kV

Conductor: Copper

Insulation: PVC

Voltage: 600/1000V

Package: Export wooden drum

Email: manager@hdcable.com.cn

Application:

2.5mm 12 Core Armoured Cable is commonly found supplying mains voltage electricity to powered devices and networks. For example, it could be used to power outdoor buildings such as garden sheds or workshops as well as garden features such as jacuzzi/hot tubs.The cable contains a steel wire armour, meaning it provides a mechanical protection for the insulating layers underneath. This also enables the cable to have higher pulling loads, making it perfectly suitable for dispensing from a cable drum on a building site, etc. It’s construction is commonly identified by the plain annealed stranded copper for the cores, the PVC (Polyvinyl Chloride) for the bedding and sheathing, armour made from steel wire and PVC (Polyvinyl Chloride) for the insulation. The Steel Wire can also be used as a CPC (Circuit Protective Conductor), meaning the armour can be used an earth for the cable. This means that even though the cable has an earth core, it is still protected, meaning it abides by all health and safety regulations.


Standard:


MS 2103 / IEC 60502 – 1



CONSTRUCTION :

 Construction:

Conductor : Plain Annealed Copper Conductor
Insulation : PVC (Polyvinyl Chloride) PVC/A
Colour of Insulation : White with black numbering
Bedding : PVC (Polyvinyl Chloride) ST1
Armoured : Galvanised Steel Wires
Sheath : PVC (Polyvinyl Chloride) ST1
Voltage : 600/1000 Volts
TECHNICAL :
 Nominal Voltage : U / U 0.6 / 1kV O
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V
PARAMETER :
 
Number of cores (mm2)
Nominal cross-sectional area (sq.mm) Construction, number/wire diameter (No./mm) Thickness of Insulation (mm) Thickness of Bedding (mm) Dianeter of steel wire (mm) Thickness of Sheath (mm) Approx.overall diameter (mm) Approx. Net Weight (kg/km)
5 1.5 7/0.53 0.6 0.8 0.9 1.4 14 456
7 1.5 7/0.53 0.6 0.8 0.9 1.4 14.9 467
9 1.5 7/0.53 0.6 0.8 1.25 1.5 18.1 693
12 1.5 7/0.53 0.6 0.8 1.25 1.5 19.1 784
19 1.5 7/0.53 0.6 0.8 1.25 1.6 21.8 1027
27 1.5 7/0.53 0.6 1 1.6 1.7 26.4 1512
37 1.5 7/0.53 0.6 1 1.6 1.8 30.1 1848
48 1.5 7/0.53 0.6 1 1.6 1.9 34.6 2246
5 2.5 7/0.67 0.7 0.8 0.9 1.5 15.9 516
7 2.5 7/0.67 0.7 0.8 1.25 1.5 17.6 707
9 2.5 7/0.67 0.7 0.8 1.25 1.6 20.6 887
12 2.5 7/0.67 0.7 0.8 1.25 1.6 21.9 1019
19 2.5 7/0.67 0.7 1 1.6 1.7 26.2 1550
27 2.5 7/0.67 0.7 1 1.6 1.8 30.4 1994
37 2.5 7/0.67 0.7 1.2 1.6 1.9 35 2508
48 2.5 7/0.67 0.7 1.2 2 2.1 41.2 3365
5 4 7/0.85 0.8 0.8 1.25 1.5 18.5 766
7 4 7/0.85 0.8 0.8 1.25 1.6 20 915
9 4 7/0.85 0.8 1 1.6 1.7 24.6 1329
12 4 7/0.85 0.8 1 1.6 1.7 26.2 1535
19 4 7/0.85 0.8 1 1.6 1.8 30 2052
Send message
SEND
RESET
Related products