Overhead Neutral-supported Multiplex Conductor:Grullo

Code Word: Grullo

Size AWG (Phase Conductors): 2/0

Voltage : 600V

Number of cores: 3+1 cores

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

2/0-2/0-2/0-2/0 Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable Application


2/0-2/0-2/0-2/0 grullo conductor quadruplex overhead service drop cable used to supply 3-phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-tophase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors

Also Known As:
2/0-2/0-2/0-2/0 grullo aluminum quadruplex, 2/0-2/0-2/0-2/0 grullo overhead service drop, 2/0-2/0-2/0-2/0 grullo three phase cable, 2/0-2/0-2/0-2/0 grullo 3 phase cable, 2/0-2/0-2/0-2/0 grullo 3 phase power cable, 2/0-2/0-2/0-2/0 grullo 3 phase extension cord, 2/0-2/0-2/0-2/0 grullo 3 phase aluminum cable, 2/0-2/0-2/0-2/0 grullo 3 phase electrical cable, 2/0-2/0-2/0-2/0 grullo three phase power cable, 2/0-2/0-2/0-2/0 grullo quadruplex wire, 2/0-2/0-2/0-2/0 grullo quadruplex overhead wire, 2/0-2/0-2/0-2/0 grullo overhead service entrance cable.

2/0-2/0-2/0-2/0 Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable Standard


• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

2/0-2/0-2/0-2/0 Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger)Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



6-6-6-6 Chola Aluminum Conductor Quadruplex Overhead Service Drop Cable 
TECHNICAL DATA :

2/0-2/0-2/0-2/0 Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
2/0-2/0-2/0-2/0 Grullo Aluminum Conductor Quadruplex Overhead Service Drop Cable Parameter

Size AWG: 2/0

Stranding: 19/w

Insulation Thickness (mils): 0.060

Neutral Size AWG: 2/0

Weight lbs./1000ft: XLP: 707

Weight lbs./1000ft: Poly: 678

Ampacity: XLP: 205

Ampacity: Poly: 160 