×
Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable

Overhead Neutral-supported Multiplex Conductor:Schnauzer

Code Word: Schnauzer

Size AWG (Phase Conductors): 2

Voltage: 600V

Number of cores: 2 cores

Package: Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Application


2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable is designed for use to supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 90°C maximum.

Also Known As:
2-2 schnauzeraluminium overhead cables, 2 schnauzer overhead aluminum wire, 2 schnauzer two conductor cable, 2 schnauzer 2 conductor power cable, 2 schnauzer two conductor, 2 schnauzer aluminum drop, 2 schnauzer overhead service drop conductors, 2 schnauzer overhead service conductors.

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
CONSTRUCTION :

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Construction

 6-6 Shepherd Aluminum Conductor Duplex Overhead Service Drop Cable


Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger. .

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.

 
TECHNICAL DATA :

2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
2-2 Schnauzer Aluminum Conductor Duplex Overhead Service Drop Cable Parameter
Code Name Schnauzer
Phas Conductor Size/AWG 2
Phase Conductor Stranding 7/w
Phase Conductor Insulation Thickness 45 mls
Bare Neutral Messenger Size/AWG 4
Bare Neutral Strand 7
Bare Neutral Messenger Breaking Strength 2800 Lbs
Weight Per (lb/1000 ft)XLP 163.3 Lbs
Weight (lb/1000 ft) Poly 156.2 Lbs
Ampacity XLP 150 Amps
Ampacity Poly 120 Amps
Send message
SEND
RESET
Related products