Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Overhead Neutral-supported Multiplex Conductor:Artemia

Code Word: Artemia

Size AWG (Phase Conductors): 4

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application


Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors. A bare messenger wire of this electrical cable is bonded closely on the two insulated aluminum conductors, which are individually insulated with black cross-linked polyethylene for protection.

4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• ICEA S-76-474-Neutral-supported Power Cable Assemblies With Weather-Resistant Extruded Insulation Rated 600Volts
 
CONSTRUCTION :

4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare AAAC messenger.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.


  
 
TECHNICAL DATA :

4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :

4-4-6 Artemia Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter

 
Code Name Artemia
Phase Conductor Size/AWG 4
Phase Conductor Stranding Solid
Phase Conductor Insulation Thickness 45 mls
Bare Neutral Messenger Size/AWG 6
Bare Neutral Messenger Stranding 7
Bare Neutral Messenger Breaking Strength 1110 Lbs
Weight Per (lb/1000 ft) XLP 141.4Lbs
Weight (lb/1000 ft) Poly 137.1 Lbs
Ampacity XLP 115 Amps
Ampacity Poly 90 Amps
 