6-6-6 Voluta Triplex Aluminum Conductor Triplex Overhead Service Drop Cable Wire

Overhead Neutral-supported Multiplex Conductor:Voluta

Code Word: Voluta

Size AWG (Phase Conductors): 6

Voltage: 600V

Number of cores: Triplex

Package : Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.


6-6-6 Voluta Triplex Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

ASTM B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

 
CONSTRUCTION :

6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor

Strand or Compressed 1350-H19 Series Aluminum Conductor.

Neutral(Messenger )Conductor

Bare ACSR messenger. Optional constructions include a messenger of AAC or 6201 alloy.

Insulation

Black Cross Linked Polyethylene (XLP) Insulation.



TECHNICAL DATA :

6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

V

600

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :

6-6-6 Voluta Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter

Code
Word
Phase Conductor Bare Neutral Messenger Weight
Per 1000ft.(Ibs.)
Allowable
Ampacities+
Size
(AWG)
Stranding Insul.
Thick.
(mils)
Size
(kcmil)
Stranding Rated Strength
(Ibs.)
XLP POLY XLP POLY
ACSR NEUTRAL-MESSENGER
Paludina 6 1 45 6 43252 1190 109 109 85 70
Voluta 6 7 45 6 43252 1190 114 114 85 70
Whelk 4 1 45 4 43252 1860 -- 164 115 90
Periwinkle 4 7 45 4 43252 1860 172 172 115 90
Conch 2 7 45 2 43252 2850 262 262 150 120
Neritina 1/0 7 60 1/0 43252 4380 420 420 205 160
Cenia 1/0 9 60 1/0 43252 4380 414 414 205 160
Runcina 2/0 7 60 2/0 43252 5310 520 520 235 185
Triton 2/0 11 60 2/0 43252 5310 512 512 235 185
Mursia 3/0 17 60 3/0 43252 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 43252 8350 789 789 315 245
Limpet 336.4 19 80 336.4 43118 8680 1167 1167 420 325
 
Send message