Type of cable: 8000 Series Aluminum Alloy Concentric Cable

Phase Conductor: Aluminum Alloy

Insulation : XLPE

Neutral Conductor: Aluminum Alloy

Sheath: PVC (XLPE/PE) sheath

Email: manager@hdcable.com.cn

8000 Series Aluminum Alloy Concentric Cable Application


The 8000 series aluminum alloy concentric cable is used in electric service entrance from the power distribution network to the meter pannel(especially where it is required to prevent electricity theft), and as feeder cable from the meter pannel to the distribution pannel.

This cable an be used in dry and wet places, outdoors or directly buried.It has a maximum operating temperature of 90ºC and rated voltage of 600V&below.

Concentric cable refers to a cable with two concentric conductors, and the conductor and the shield layer share the same axis. It is usually used in distribution networks, current surface boards, meters or circuit panels, which can be placed directly underground or outdoors , Even suitable for dry and humid environments, can support high-bandwidth communications on relatively long lines without repeaters.
STANDARD :

8000 Series Aluminum Alloy Concentric Cable Standard


ASTM D2655, ASTM B556, ASTM B193, UL 44, UL 1581, ASTM B8, UL 854, NEC Numeral 310.14
CONSTRUCTION :

 8000 Series Aluminum Alloy Flat Concentric Cable ASTM Standard
1.Phase conductor: Aluminum alloy conductor 8000 series
2.Insulation :XLPE
3.Neutral conductor :Aluminum alloy conductor 8000 series
4.Binder tape :Non-hygroscopic tape
5.Sheathed:PVC (XLPE/PE) sheath

 

PARAMETER :

8000 Series Aluminum Alloy Concentric Cable 3X8AWG

ASTM Standard

Core and
Nominal Cross Section
Conductor Insulation
 Thickness
Concentric conductor Thickness
of cable shield
Overall 
Diameter
Cable
Weight
Max DC resistance of conductor (20℃)
Wire gauge Number Diameter mm mm Number Diameter mm mm mm kg/km Ω/km (Phase) Ω/km (Concentric)
Copper conductor (US standard)
2X #12 7 0.78 1.14 39 0.321 1.14 7.74 108 5.43 5.50
2X #10 7 0.98 1.14 25 0.511 1.14 8.72 151 3.41 3.50
2X #8 7 1.23 1.14 25 0.643 1.14 9.74 214 2.14 2.20
2X #6 7 1.55 1.14 25 0.813 1.14 11.04 313 1.35 1.40
2X #4 7 1.96 1.14 26 1.020 1.14 12.68 472 0.848 0.85
3X #8 7 1.23 1.14 65 0.405 1.14 11.3X17.3 418 2.14 2.20
3X #6 7 1.55 1.14 65 0.511 1.52 13.2X20.2 620 1.35 1.40
3X #4 7 1.96 1.14 65 0.643 1.52 14.7X22.9 875 0.848 0.85
3X #2 7 2.47 1.14 65 0.823 1.52 16.6X26.3 1275 0.524 0.53
Aluminum alloy conductor (US standard)
2X #12 7 0.78 1.14 39 0.321 1.14 7.74 67 8.88 8.90
2X #10 7 0.98 1.14 25 0.511 1.14 8.72 85 5.59 5.60
2X #8 7 1.23 1.14 25 0.643 1.14 9.74 110 3.52 3.60
2X #6 7 1.55 1.14 25 0.813 1.14 11.04 148 2.21 2.30
2X #4 7 1.96 1.14 26 1.020 1.14 12.68 206 1.39 1.40
3X #8 7 1.23 1.14 65 0.405 1.14 11.3X17.3 262 3.52 3.60
3X #6 7 1.55 1.14 65 0.511 1.52 13.2X20.2 370 2.21 2.30
3X #4 7 1.96 1.14 65 0.643 1.52 14.7X22.9 488 1.39 1.40
3X #2 7 2.47 1.14 65 0.823 1.52 16.6X26.3 640 0.88 0.89