Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
8000 Series Aluminum Alloy Flat Concentric Cable IEC Standard

8000 Series Aluminum Alloy Flat Concentric Cable IEC Standard

Type of cable: 8000 Series Aluminum Alloy Concentric Cable

Phase Conductor: Aluminum Alloy

Insulation : XLPE

Neutral Conductor: Aluminum Alloy

Sheath: PVC (XLPE/PE) sheath

Email: manager@hdcable.com.cn

8000 Series Aluminum Alloy Concentric Cable Application


The 8000 series aluminum alloy concentric cable is used in electric service entrance from the power distribution network to the meter pannel(especially where it is required to prevent electricity theft), and as feeder cable from the meter pannel to the distribution pannel.

This cable an be used in dry and wet places, outdoors or directly buried.It has a maximum operating temperature of 90ºC and rated voltage of 600V&below.

Concentric cable refers to a cable with two concentric conductors, and the conductor and the shield layer share the same axis. It is usually used in distribution networks, current surface boards, meters or circuit panels, which can be placed directly underground or outdoors , Even suitable for dry and humid environments, can support high-bandwidth communications on relatively long lines without repeaters.
STANDARD :

8000 Series Aluminum Alloy Concentric Cable Standard


IEC60502-1, BS7870, ASTMD2655
ASTMB556, ASTMB193, ASTMB8, UL44, UL1581, UL854
CONSTRUCTION :

 8000 Series Aluminum Alloy Flat Concentric Cable IEC Standard

1.Phase conductor: Aluminum alloy conductor 8000 series
2.Insulation :XLPE
3.Neutral conductor :Aluminum alloy conductor 8000 series
4.Binder tape :Non-hygroscopic tape
5.Sheathed:PVC (XLPE/PE) sheath

PARAMETER :

8000 Series Aluminum Alloy Concentric Cable IEC Standard

Core and
Nominal Cross Section
Conductor Insulation
Thickness
Concentric Conductor Thickness of Cable Shield Overall
Diameter
Weight of cable Max DC resistance of conductor (20℃)
mm2 Number Diameter mm mm Number Diameter mm mm mm kg/km Ω/km (Phase) Ω/km (Concentric)
Copper conductor (IEC standard)
2X10 7 1.35 1.55 20 0.85 1.40 11.80 290 1.83 1.90
2X16 7 1.70 1.55 32 0.85 1.40 12.84 420 1.15 1.20
2X25 7 2.14 1.60 29 1.13 1.50 15.02 630 0.727 0.76
2X35 19 1.53 1.65 27 1.35 1.60 17.00 832 0.524 0.55
Aluminum alloy conductor (IEC standard)
2X10 7 1.35 1.55 23 1.13 1.40 12.41 192 3.08 1.335
2X16 7 1.70 1.55 26 1.13 1.40 13.46 230 1.91 1.808
2X25 7 2.14 1.6 29 1.13 1.50 15.08 290 1.20 1.0586
2X35 19 1.53 1.65 27 1.35 1.60 17.05 370 0.868 0.7966