Cable SAC Aluminum Spaced Aerial Cable 11kV 15kV 25kV 35kV
Conductor: Compact stranded hard drawn Aluminium Conductor ( Class2)
Conductor shield: Semi-conducting cross-linked polyethylene.
Insulation: Cross-linked polyethylene (Natural)
Sheath: Track resistant cross-linked polyethylene (Black)
Package : Export wooden drum & iron wooden drum or as customer require
Email: manager@hdcable.com.cn
Temperature :
Voltage rating :
15 kV phase to phase AC TESTING VOLTAGE : 27 kV for 5 minutes11KV SAC Cable
Part Number |
Cross |
Stranding |
Approx |
Approx |
Gland Size |
Single Cleat |
Nom. Max. |
Current Rating |
mm2 |
mm |
kg/km | mm | mm | mm |
ohm/km |
amp |
|
1 Core: Brown Tape |
||||||||
11KVPVC1X50 |
1 x 50 |
19/1.78 |
1210 |
28.5 |
32 |
1.2 |
0.387 |
221 |
11KVPVC1X70 |
1 x 70 |
19/2.14 |
1500 |
30.5 |
32 |
1.2 |
0.268 |
270 |
11KVPVC1X95 |
1 x 95 |
19/2.52 |
1700 |
32.4 |
32 |
1.4 |
0.193 |
321 |
11KVPVC1X120 |
1 x 120 |
37/2.03 |
2105 |
34.2 |
40 |
1.4 |
0.153 |
363 |
11KVPVC1X150 |
1 x 150 |
37/2.25 |
2505 |
36.4 |
40 |
1.6 |
0.124 |
410 |
11KVPVC1X185 |
1 x 185 |
37/2.52 |
2900 |
37.7 |
40 |
1.6 |
0.0991 |
455 |
11KVPVC1X240 |
1 x 240 |
61/2.25 |
3532 |
40.6 |
50s |
1.6 |
0.0754 |
520 |
11KVPVC1X300 |
1 x 300 |
61/2.52 |
4230 |
42.7 |
50s |
1.8 |
0.0601 |
580 |
1 Core: Brown Tape |
||||||||
11KVPVC1X400 |
1 x 400 |
61/2.85 |
5145 |
46.4 |
50s |
2 |
0.047 |
650 |
11KVPVC1X500 |
1 x 500 |
61/3.20 |
6450 |
51 |
50 |
2 |
0.0366 |
710 |
11KVPVC1X630 |
1 x 630 |
127/2.52 |
7950 |
59.9 |
63s |
R9 |
0.0283 |
761 |
11KVPVC1X800 |
1 x 800 |
127/2.85 |
9720 |
60 |
63 |
R10 |
0.0221 |
812 |
11KVPVC1X1000 |
1 x 1000 |
127/3.2 |
11860 |
64 |
75s |
R11 |
0.0176 |
868 |
15 kV SAC Cable
Nominal cross–sectional area mm² |
Minimum number of wire No. |
Diameter of conductor (Approx.) mm |
Thickness of insulation mm |
Thickness of sheath |
Overall diameter (Approx.) |
Maximum DC. conductor resistance at 20°C |
Minimum insulation resistance at 15.6°C M Ω-km |
Allowable amp acitiesin free air at40°C ambient A |
Cable weight (Approx.) kg/km |
35 |
6 |
6.9 |
1.91 |
1.91 |
16 |
0.868 |
1820 |
151 |
232 |
50 |
6 |
8 |
1.91 |
1.91 |
17.5 |
0.641 |
1612 |
187 |
291 |
70 |
12 |
9.8 |
1.91 |
1.91 |
19 |
0.443 |
1445 |
231 |
358 |
95 |
15 |
11.4 |
1.91 |
1.91 |
21 |
0.32 |
1284 |
281 |
451 |
120 |
15 |
12.9 |
1.91 |
1.91 |
22.5 |
0.253 |
1152 |
324 |
552 |
150 |
15 |
14.1 |
1.91 |
1.91 |
24 |
0.206 |
1070 |
375 |
639 |
185 |
30 |
15.8 |
1.91 |
1.91 |
25.5 |
0.164 |
980 |
433 |
763 |
240 |
30 |
18.3 |
1.91 |
1.91 |
28 |
0.125 |
874 |
525 |
953 |
25 kV SAC Cable
Nominal cross–sectional area mm² |
Minimum number of wire No. |
Diameter of conductor (Approx.) |
Thickness of insulation |
Thickness of sheath |
Overall diameter (Approx.) |
Maximum DC. conductor resistance at 20°C |
Minimum insulation resistance at 15.6°C M |
Allowable amp acitiesin free air at40°C |
Cable weight (Approx.) |
35 |
6 |
6.9 |
3.18 |
3.18 |
21 |
0.868 |
2580 |
149 |
363 |
50 |
6 |
8 |
3.18 |
3.18 |
22 |
0.641 |
2314 |
186 |
432 |
70 |
12 |
9.8 |
3.18 |
3.18 |
24.5 |
0.443 |
2100 |
229 |
509 |
95 |
15 |
11.4 |
3.18 |
3.18 |
26 |
0.32 |
1887 |
279 |
615 |
120 |
15 |
12.9 |
3.18 |
3.18 |
27 |
0.253 |
1712 |
321 |
729 |
150 |
15 |
14.1 |
3.18 |
3.18 |
29.5 |
0.206 |
1600 |
371 |
826 |
185 |
30 |
15.8 |
3.18 |
3.18 |
31 |
0.164 |
1477 |
429 |
959 |
240 |
30 |
18.3 |
3.18 |
3.18 |
33.5 |
0.125 |
1328 |
520 |
1170 |
35 kV SAC Cable
Nominal cross–sectional area mm² |
Minimum number of wire No. |
Diameter of conductor (Approx.) |
Thickness of insulation |
Thickness of sheath |
Overall diameter (Approx.) |
Maximum DC. conductor resistance at 20°C |
Minimum insulation resistance at 15.6°C M |
Allowable amp acitiesin free air at40°C |
Cable weight (Approx.) |
50 |
6 |
8 |
4.45 |
3.18 |
25.5 |
0.641 |
2606 |
184 |
517 |
70 |
12 |
9.8 |
4.45 |
3.18 |
27.5 |
0.443 |
2375 |
227 |
599 |
95 |
15 |
11.4 |
4.45 |
3.18 |
29 |
0.32 |
2144 |
276 |
711 |
120 |
15 |
12.9 |
4.45 |
3.18 |
31 |
0.253 |
1952 |
318 |
831 |
150 |
15 |
14.1 |
4.45 |
3.18 |
32.5 |
0.206 |
1830 |
367 |
933 |
185 |
30 |
15.8 |
4.45 |
3.18 |
33.5 |
0.164 |
1694 |
425 |
1073 |
240 |
30 |
18.3 |
4.45 |
3.18 |
36.5 |
0.125 |
1529 |
515 |
1293 |