Copper Conductor Quadruplex Service Drop Cable 600V

Copper Conductor Quadruplex Service Drop Cable 600V

Conductor: Stranded compressed soft copper

Insulation: Thermoplastic Polyethylene or Cross-linked Polyethylene

Voltage: 600V

Number of cores: Quadruplex

Package: Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

Copper Quadruplex Service Drop Cable Application

Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for cross-linked polyethylene (XLP) insulated conductors.

Copper Quadruplex Service Drop Cable Specifications

Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire.
B-3 Soft or Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and cross-linked polyethylene insulated conductors.

 
CONSTRUCTION :

Copper Quadruplex Overhead Service Drop Cable Wire Construction


Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.-Theta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun. 
TECHNICAL DATA :

Copper Quadruplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
PARAMETER :
Quadruplex Cable – Copper Service Drop Cable Wire Parameter
Code Word Copper Phase Conductor Bare Copper Neutral Messenger Weight Per 1000 Ft. (lbs.) Allowable Ampacities+
Size (AWG) Stranding Insulation Thickness (mils.) Size (AWG) Stranding Rated Strength (lbs.) Polyethylene XLP Polyethylene XLP
Atlanta 6 7 45 6 Solid 1280 368 374 75 95
Tallahassee 6 7 45 6 7 1228 369 376 75 95
Richmond 4 7 45 4 7 1938 573 581 100 125
Baton Rouge 4 7 45 4 Solid 1970 570 578 100 125
Jackson 2 7 45 2 Solid 3003 889 889 135 170
Seattle 2 7 45 2 7 3050 893 893 135 170
Nashville 1/0 19 60 1/0 7 4752 1420 1457 180 230
Lincoln 2/0 19 60 2/0 7 5926 1773 1773 205 265
Raleigh 3/0 19 60 3/0 7 7366 2220 2220 235 305
Denver 4/0 19 60 4/0 7 9154 2781 2803 270 350