×
Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
Copper Conductor Triplex Service Drop Cable 600V

Copper Conductor Triplex Service Drop Cable 600V

Conductor: Stranded compressed soft copper

Insulation: Thermoplastic Polyethylene or Cross-linked Polyethylene

Voltage: 600V

Number of cores: Triplex

Package: Export wooden drum & iron wooden drum or as customer require

Email: manager@hdcable.com.cn

Copper Triplex Service Drop Cable Application

Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for cross-linked polyethylene (XLP) insulated conductors.

Copper Triplex Service Drop Cable Specifications

Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire.
B-3 Soft or Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and cross-linked polyethylene insulated conductors. 
 
CONSTRUCTION :

Copper Triplex Overhead Service Drop Cable Wire Construction


Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
Code words for XLP insulated products are formed by adding ""XLP"" to the conventional polyethylene code words above (e.g.-Theta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun. 
 
TECHNICAL DATA :

Copper Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

 
 
PARAMETER :

Triplex Cable – Copper Service Drop Cable Wire Parameter

Code Word Copper Phase Conductor Bare Copper Neutral Messenger Weight Per 1000 Ft. (lbs.) Allowable Ampacities+
Size (AWG) Stranding Insulation Thickness (mils.) Size (AWG) Stranding Rated Strength (lbs.) Polyethylene XLP Polyethylene XLP
Pica 8 7 45 10 SOLID 529 164 168 70 85
Biodoni 8 7 45 8 SOLID 826 185 189 70 85
Garamond 8 7 45 8 7 777 186 190 70 85
Tudor 6 7 45 8 SOLID 826 254 260 90 110
Futura 6 7 45 6 SOLID 1280 281 288 90 110
Gothic 6 7 45 6 7 1228 285 291 90 110
Nonpareil 4 7 45 6 SOLID 1280 390 396 115 145
Ionic 4 7 45 4 SOLID 1970 438 443 115 145
Caslon 4 7 45 4 7 1938 442 447 115 145
Minion 2 7 45 4 SOLID 1970 609 617 155 195
Primer 2 7 45 4 7 1938 614 622 155 195
Century 2 7 45 2 7 3050 692 701 155 195
Corinthian 1/0 19 60 1/0 7 4752 1055 1066 205 265
Doric 2/0 19 60 2/0 7 5926 1319 1331 235 300
Tuscan 3/0 19 60 3/0 7 7366 1665 1667 275 350
Composite 4/0 19 60 4/0 7 9154 2088 2085 315 405
 
Send message
SEND
RESET
Related products