KVV22 Control Cable-PVC Insulated Steel Tape Armoured Copper Cables

KVV22 Control Cable-PVC Insulated Steel Tape Armoured Copper Cables

Voltage Rating: 450/750 Volts,

Conductor: soft annealed copper

Insulation: PVC

Armoured material Steel tape

Sheath PVC

Email: manager@hdcable.com.cn

KVV22 Control Cable Application

KVV22 PVC Insulated Cable belongs to the control cable in the cables for electrical installations. It has good high temperature resistance, cold resistance and aging resistance. It is generally used for control and monitoring circuits and protection circuits. In addition, flame-retardant, fire-resistant and low-smoke and halogen-free control cables can be produced according to user requirements. 

KVV22 Cable Standard

IEC 60227, IEC 60502, GB/T 9330, BS 6500
CONSTRUCTION :

Control Cable Types

Model

Name

Main application

KVV

Copper conductor PVC insulated PVC sheathed control cable

For laying indoors, in trenches and in ducts, for fixed  installation

KVVP

Copper conductor PVC insulated PVC sheathed copper braiding screened control cable

For laying indoors, in trenches and in dusts, for fixed installation

KVVP2

Copper conductor PVC insulated and sheathed control cable with steel tape shield

For laying indoors, in trenches and in dusts and in ground, able

to withstand heavier mechanical force, for fixed installation

KVV22

Copper conductor PVC insulated and sheathed control cable with steel tape armour

For laying indoors, in trenches and in dusts and in ground, able

to withstand heavier mechanical force, for fixed installation

KVVR

Copper conductor PVC insulated flexible control cable

For laying indoors, movable and flexible

ZR-KVVRP

Copper conductor PVC insulated PVC sheathed flame retardant flexible control cable with braided shield

Fixed laying indoors with capability of moving and screening

ZR-KVV

Copper conductor PVC insulated and sheathed flame retardant control cable

For laying indoors, in trenches, in ducts and for fixed installation,

the cable should be flame retardant

ZR-KVVP2

Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape shield

For laying indoors, in trenches, in ducts and for fixed installation,

 the cable should be flame retardant

ZR-KVV22

Copper conductor PVC insulated and sheathed flame retardant control cable with steel tape armour

For laying indoors, in trenches, in ducts and underground, the

cable should be flame-retardant and able to bear beavier

external mechanical force, and for fixed installation

ZR-KVVR

Copper conductor PVC insulated and sheathed flame retardant flexible control cable

For laying indoors, and the cable should be flexible and movablea

TECHNICAL DATA :

KVV22 Control Cable Technical Data

STANDARD IEC 60227, IEC 60502, GB/T 9330, BS 6500
APPLICATION Industral Use
CHEMICAL PERFORMANCE Chemical & Oil resistance: Good
MECHANICAL PERFORMANCE Minimum bending raduis: x20cable diameter 
FIRE PERFORMANCE Flame non-propagation base on IEC 60332-1
Reduced emission of Halogens chlorine<15%
TERMINAL PERFORMANCE Maximum service temperature: 70°C
Maximum short-circuit temperature: 160°C(max. 5s)
Minimum service temperature: -15°C

 
PARAMETER :

KVV22 Control Cable CU/PVC/STA/PVC

Nominal
Size
Conductor Structure Insulation Thickness Thickness of Inner Sheath  Thickness of Steel Tape Sheath Thickness Approx. Overall Dia. Approx. Weight Nominal
Size
Conductor Structure Insulation Thickness Thickness of Inner Sheath  Thickness of Steel Tape Sheath Thickness Approx. Overall Dia. Approx. Weight
mm2 No./mm mm mm mm mm mm kg/km mm2 No./mm mm mm mm mm mm kg/km
5×0.75 1/0.97 0.6 1.1  0.2  1.5  12.00  231 5×0.75 7/0.37 0.6 1.1  0.2  1.5  12.39  241
6×0.75 1/0.97 0.6 1.1  0.2  1.5  12.67  258 6×0.75 7/0.37 0.6 1.1  0.2  1.5  13.11  271
7×0.75 1/0.97 0.6 1.1  0.2  1.5  12.67  264 7×0.75 7/0.37 0.6 1.1  0.2  1.5  13.11  276
8x0.75 1/0.97 0.6 1.1  0.2  1.5  13.35  289 8x0.75 7/0.37 0.6 1.2  0.2  1.5  13.83  303
10x0.75 1/0.97 0.6 1.2  0.2  1.5  14.93  348 10x0.75 7/0.37 0.6 1.2  0.2  1.5  15.51  366
12x0.75 1/0.97 0.6 1.2  0.2  1.5  15.28  373 12x0.75 7/0.37 0.6 1.2  0.2  1.5  15.88  391
14x0.75 1/0.97 0.6 1.2  0.2  1.5  15.87  407 14x0.75 7/0.37 0.6 1.2  0.2  1.5  16.51  427
16x0.75 1/0.97 0.6 1.2  0.2  1.5  16.51  445 16x0.75 7/0.37 0.6 1.2  0.2  1.5  17.20  468
19x0.75 1/0.97 0.6 1.2  0.2  1.5  17.19  490 19x0.75 7/0.37 0.6 1.2  0.2  1.5  17.92  515
24x0.75 1/0.97 0.6 1.2  0.2  1.7  19.64  606 24x0.75 7/0.37 0.6 1.2  0.2  1.7  20.52  638
27x0.75 1/0.97 0.6 1.2  0.2  1.7  19.99  642 27x0.75 7/0.37 0.6 1.2  0.2  1.7  20.89  676
30x0.75 1/0.97 0.6 1.2  0.2  1.7  20.58  688 30x0.75 7/0.37 0.6 1.2  0.2  1.7  21.51  724
37x0.75 1/0.97 0.6 1.2  0.2  1.7  21.90  795 37x0.75 7/0.37 0.6 1.2  0.2  1.7  22.92  837
44x0.75 1/0.97 0.6 1.2  0.2  1.7  24.16  928 44x0.75 7/0.37 0.6 1.2  0.2  1.7  25.12  965
48x0.75 1/0.97 0.6 1.2  0.2  1.7  24.31  963 48x0.75 7/0.37 0.6 1.2  0.2  1.7  25.49  1014
52x0.75 1/0.97 0.6 1.2  0.2  1.7  24.89  1020 52x0.75 7/0.37 0.6 1.2  0.2  1.7  26.12  1075
61x0.75 1/0.97 0.6 1.2  0.2  1.7  26.22  1149 61x0.75 7/0.37 0.6 1.2  0.2  1.7  27.53  1211
 