0.6/1kV Aluminum Conductor Low Voltage Power Cable with XLPE Insulation and PVC Sheath AL-XLPE-PVC
Conductor: Aluminum
Insulation: XLPE
Sheath: Polyvinylchloride compound PVC 5V-90
Voltage : 0.6/1kV
Number of cores: Multi Core
Package : Export wooden drum & iron wooden drum or as customer require
Email: manager@hdcable.com.cn
Voltage Rating Uo/U (Um) 0.6/1 (1.2)kV
Nominal Voltage DC (core-earth/core-core) :1.8/1.8kV
Test Voltage:4kV
Temperature Rating:
Flexed: 5°C to +90°C
Fixed: -35°C to +90°C
Maximum Short Circuit Temperature:
+250°C (max 5 seconds)
Minimum Bend Radius:
Single core: 15 x overall diameter
Multi core: 12 x overall diameter
0.6/1kV-1 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
1X10 | 0.7 | 1.4 | 8.0 | 75 | 3.08 | 55 | 71 |
1X16 | 0.7 | 1.4 | 9.0 | 106 | 1.91 | 71 | 91 |
1X25 | 0.9 | 1.4 | 10.6 | 150 | 1.20 | 94 | 115 |
1X35 | 0.9 | 1.4 | 11.6 | 180 | 0.868 | 115 | 140 |
1X50 | 1.0 | 1.4 | 13.1 | 240 | 0.641 | 140 | 165 |
1X70 | 1.1 | 1.4 | 15.0 | 320 | 0.443 | 180 | 205 |
1X95 | 1.1 | 1.5 | 16.8 | 400 | 0.320 | 220 | 245 |
1X120 | 1.2 | 1.5 | 18.4 | 500 | 0.253 | 260 | 280 |
1X150 | 1.4 | 1.6 | 20.5 | 600 | 0.206 | 300 | 315 |
1X185 | 1.6 | 1.6 | 22.6 | 730 | 0.164 | 350 | 360 |
1X240 | 1.7 | 1.7 | 25.2 | 930 | 0.125 | 414 | 420 |
1x300 | 1.8 | 1.8 | 27.8 | 1140 | 0.100 | 485 | 475 |
1x400 | 2.0 | 1.9 | 31.4 | 1500 | 0.0778 | 570 | 545 |
1x500 | 2.2 | 2.0 | 34.9 | 1800 | 0.0605 | 670 | 620 |
1X630 | 2.4 | 2.2 | 39.1 | 2285 | 0.0469 | 790 | 705 |
0.6/1kV-2 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
2X10 | 0.7 | 1.8 | 15.4 | 200 | 3.08 | 58 | 78 |
2X16 | 0.7 | 1.8 | 17.4 | 270 | 1.91 | 75 | 100 |
2X25 | 0.9 | 1.8 | 20.5 | 380 | 1.20 | 100 | 130 |
2X35 | 0.9 | 1.8 | 22.5 | 480 | 0.868 | 120 | 155 |
2X50 | 1.0 | 1.8 | 20.3 | 490 | 0.641 | 150 | 185 |
2X70 | 1.1 | 1.8 | 23.3 | 630 | 0.443 | 190 | 225 |
2X95 | 1.1 | 1.9 | 26.2 | 820 | 0.320 | 235 | 275 |
2X120 | 1.2 | 2.0 | 29.4 | 1000 | 0.253 | 275 | 315 |
2X150 | 1.4 | 2.2 | 32.6 | 1250 | 0.206 | 315 | 350 |
2X185 | 1.6 | 2.3 | 36.0 | 1540 | 0.164 | 365 | 395 |
0.6/1kV-3 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
3X10 | 0.7 | 1.8 | 17.2 | 250 | 3.08 | 50 | 66 |
3X16 | 0.7 | 1.8 | 19.4 | 330 | 1.91 | 65 | 85 |
3X25 | 0.9 | 1.8 | 22.8 | 480 | 1.20 | 87 | 110 |
3X35 | 0.9 | 1.8 | 25.0 | 580 | 0.868 | 105 | 130 |
3X50 | 1.0 | 1.8 | 24.4 | 670 | 0.641 | 130 | 160 |
3X70 | 1.1 | 1.9 | 29.4 | 910 | 0.443 | 165 | 195 |
3X95 | 1.1 | 2.0 | 33.6 | 1170 | 0.320 | 205 | 235 |
3X120 | 1.2 | 2.1 | 35.9 | 1460 | 0.253 | 240 | 265 |
3X150 | 1.4 | 2.3 | 39.9 | 1820 | 0.206 | 270 | 300 |
3X185 | 1.6 | 2.4 | 44.1 | 2200 | 0.164 | 315 | 340 |
3X240 | 1.7 | 2.6 | 51.1 | 2850 | 0.125 | 375 | 395 |
3X300 | 1.8 | 2.7 | 56.1 | 3500 | 0.100 | 435 | 445 |
3X400 | 2.0 | 3.0 | 62.4 | 4500 | 0.0778 | 510 | 510 |
0.6/1kV-4 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
4X10 | 0.7 | 1.8 | 18.6 | 300 | 3.08 | 50 | 66 |
4X16 | 0.7 | 1.8 | 21.0 | 400 | 1.91 | 65 | 85 |
4X25 | 0.9 | 1.8 | 24.9 | 570 | 1.20 | 87 | 110 |
4X35 | 0.9 | 1.8 | 28.3 | 710 | 0.868 | 105 | 130 |
4X50 | 1.0 | 1.8 | 28.4 | 850 | 0.641 | 130 | 160 |
4X70 | 1.1 | 2.0 | 33.1 | 1160 | 0.443 | 165 | 195 |
4X95 | 1.1 | 2.1 | 37.1 | 1520 | 0.320 | 205 | 235 |
4X120 | 1.2 | 2.2 | 40.8 | 1898 | 0.253 | 240 | 265 |
4X150 | 1.4 | 2.4 | 45.2 | 2369 | 0.206 | 270 | 300 |
4X185 | 1.6 | 2.6 | 52.1 | 2925 | 0.164 | 315 | 340 |
4X240 | 1.7 | 2.8 | 57.8 | 3700 | 0.125 | 375 | 395 |
4X300 | 1.8 | 3.0 | 63.5 | 4580 | 0.100 | 435 | 445 |
4X400 | 2.0 | 3.3 | 70.9 | 5800 | 0.0778 | 510 | 510 |
0.6/1kV-5 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
5X10 | 0.7 | 1.8 | 18.8 | 360 | 3.08 | 50 | 66 |
5X16 | 0.7 | 1.8 | 21.8 | 485 | 1.91 | 65 | 85 |
5X25 | 0.9 | 1.8 | 26.2 | 690 | 1.20 | 87 | 110 |
5X35 | 0.9 | 1.8 | 28.0 | 865 | 0.868 | 105 | 130 |
5X50 | 1.0 | 1.9 | 32.4 | 1138 | 0.641 | 130 | 160 |
5X70 | 1.1 | 2.1 | 37.4 | 1575 | 0.443 | 165 | 195 |
5X95 | 1.1 | 2.2 | 41.7 | 2068 | 0.320 | 205 | 235 |
5X120 | 1.2 | 2.4 | 46.2 | 2550 | 0.253 | 240 | 265 |
5X150 | 1.4 | 2.6 | 53.1 | 3165 | 0.206 | 270 | 300 |
5X185 | 1.6 | 2.8 | 58.9 | 3950 | 0.164 | 315 | 340 |
5X240 | 1.7 | 3.0 | 65.6 | 5025 | 0.125 | 375 | 395 |
5X300 | 1.8 | 3.2 | 72.0 | 6190 | 0.100 | 435 | 445 |
0.6/1kV-3+1 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
3X16+1X10 | 0.7/0.7 | 1.8 | 19.4 | 370 | 1.91/3.08 | 65 | 85 |
3X25+1X16 | 0.9/0.7 | 1.8 | 22.8 | 520 | 1.20/1.91 | 87 | 110 |
3X35+1X16 | 0.9/0.7 | 1.8 | 25.1 | 650 | 0.868/1.91 | 105 | 130 |
3X50+1X25 | 1.0/0.9 | 1.8 | 28.2 | 780 | 0.641/1.20 | 130 | 160 |
3X70+1X35 | 1.1/0.9 | 1.9 | 31.9 | 1050 | 0.443/0.868 | 165 | 195 |
3X95+1X50 | 1.1/1.0 | 2.1 | 35.7 | 1460 | 0.320/0.641 | 205 | 235 |
3X120+1X70 | 1.2/1.1 | 2.2 | 39.6 | 1820 | 0.253/0.443 | 240 | 265 |
3X150+1X70 | 1.4/1.1 | 2.3 | 43.6 | 2150 | 0.206/0.443 | 270 | 300 |
3X185+1X95 | 1.6/1.1 | 2.5 | 49.8 | 2725 | 0.164/0.320 | 315 | 340 |
3X240+1X120 | 1.7/1.2 | 2.7 | 55.3 | 3480 | 0.125/0.253 | 375 | 395 |
3X300+1X150 | 1.8/1.4 | 2.9 | 57.0 | 4230 | 0.100/0.206 | 435 | 445 |
3X400+1X185 | 2.0/1.7 | 3.1 | 70.0 | 5520 | 0.0778/0.164 | 510 | 510 |
0.6/1kV-4+1 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
4X16+1X10 | 0.7/0.7 | 1.8 | 21.3 | 450 | 1.91/3.08 | 65 | 85 |
4X25+1X16 | 0.9/0.7 | 1.8 | 25.7 | 650 | 1.20/1.91 | 87 | 110 |
4X35+1X16 | 0.9/0.7 | 1.8 | 28.2 | 795 | 0.868/1.91 | 105 | 130 |
4X50+1X25 | 1.0/0.9 | 1.9 | 28.9 | 1020 | 0.641/1.20 | 130 | 160 |
4X70+1X35 | 1.1/0.9 | 2.0 | 32.2 | 1360 | 0.443/0.868 | 165 | 195 |
4X95+1X50 | 1.1/1.0 | 2.2 | 36.9 | 1870 | 0.320/0.641 | 205 | 235 |
4X120+1X70 | 1.2/1.1 | 2.3 | 40.8 | 2342 | 0.253/0.443 | 240 | 265 |
4X150+1X70 | 1.4/1.1 | 2.5 | 44.7 | 2778 | 0.206/0.443 | 270 | 300 |
4X185+1X95 | 1.6/1.1 | 2.7 | 50.7 | 3495 | 0.164/0.320 | 315 | 340 |
4X240+1X120 | 1.7/1.2 | 2.9 | 56.4 | 4416 | 0.125/0.253 | 375 | 395 |
4X300+1X150 | 1.8/1.4 | 3.1 | 64.0 | 5422 | 0.100/0.206 | 435 | 445 |
0.6/1kV-3+2 core aluminum conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
3X16+2X10 | 0.7/0.7 | 1.8 | 20.8 | 425 | 1.91/3.08 | 65 | 85 |
3X25+2X16 | 0.9/0.7 | 1.8 | 25.2 | 600 | 1.20/1.91 | 87 | 110 |
3X35+2X16 | 0.9/0.7 | 1.8 | 26.8 | 720 | 0.868/1.91 | 105 | 130 |
3X50+2X25 | 1.0/0.9 | 1.9 | 28.7 | 955 | 0.641/1.20 | 130 | 160 |
3X70+2X35 | 1.1/0.9 | 2.0 | 33.7 | 1230 | 0.443/0.868 | 165 | 195 |
3X95+2X50 | 1.1/1.0 | 2.2 | 38.3 | 1706 | 0.320/0.641 | 205 | 235 |
3X120+2X70 | 1.2/1.1 | 2.3 | 43.2 | 2180 | 0.253/0.443 | 240 | 265 |
3X150+2X70 | 1.4/1.1 | 2.4 | 46.5 | 2525 | 0.206/0.443 | 270 | 300 |
3X185+2X95 | 1.6/1.1 | 2.6 | 51.9 | 3195 | 0.164/0.320 | 315 | 340 |
3X240+2X120 | 1.7/1.2 | 2.8 | 58.0 | 4050 | 0.125/0.253 | 375 | 395 |
3X300+2X150 | 1.8/1.4 | 3.0 | 64.2 | 4983 | 0.100/0.206 | 435 | 445 |