THHN THWN Wire 8.0mm2 14mm2 22mm2 30mm2 38mm2 50mm2 60mm2 80mm2 100mm2 Philippines

Name : THHN THWN Wire 8.0mm2 14mm2 22mm2 30mm2 38mm2 50mm2 60mm2 80mm2 100mm2 Philippines

Conductor Copper Conductor ( Solid , Stranded )

Insulation : PVC

Sheath: Nylon

Number of cores: Single Core

Package : 100 Meters One Roll with Export Wooden Case & Pallet

Email: manager@hdcable.com.cn

THHN Wire Application


The copper conductors type THHN are used for power and lighting circuits in industrial, commercial and residential facilities, they are specially suitable for special installations through difficult ducts and to be used in abrasive zones or polluted with oils, grease, gasoline, etc. and other corrosive chemical substances as paints, solvents, etc., This type of conductor when it is used as THHN it can be used in dry places with maximum temperature of operation of 90 ºC. Regarding the voltage of service, for all the applications, it is of 600 V.

 


Standard :

THHN Wire Standards:


The copper conductors type THHN meets the following specifications and standards:
• ASTM B-3:Copper Annealed or Soft Wires.
• ASTM B-8:Copper Stranded Conductors in Concentric Layers, Hard, Semi-hard or Soft.
• UL - 83:Wires and Cables Insulated with Thermoplastic Material.
• NEMA WC-5:Wires and Cables Insulated with Thermoplastic Material (ICEA S-61-402) for Transmission and Distribution of Electric Power.

Construction :

 THHN Wire Construction


The conductors type THHN or THWN-2 can be solid or stranded and they are built with soft temper copper, they are also insulated with an uniform layer of Chloride of Polyvinyl (PVC) thermoplastic material resistant to the moisture and the heat, over which it is applied a protector coating of Nylon or Polyamide. They can be supplied in varied colors according to their size and with different packaging.
 
Thhn wire structure

Copper Conductor
Insulation of Thermoplastic Material, PVC 600V. - 90 °C
Nylon Jacket
Parameter :
 
SIZE OF CONDUCTOR No.&Nominal Diameter of Wire Wall Thickness Approximate Overall Diameter Minimum Insulation Resistance *Ampacity Cable Nominal Weight
MM Approximate AWG MM MM MM M-Ohm-Km 90℃ wet 90 ℃ dry KG/KM
Solid   PVC Nylon          
1.6mm 14 1x1.60mm 0.4 0.10 2.60 130 35 35 22.62
2.0 mm 12 1x2.00mm 0.4 0.10 3.00 110 40 40 33.57
2.6 mm 10 1x2.60mm 0.5 0.10  3.80 120 55 55 55.78
3.2 mm 8 1x3.20mm 0.8 0.13 5.06 120 75 75 88.33
Stranded                
2.0mm2 14/7 7X0.60mm 0.4 0.10 2.80 130 30 35 23.51
3.5mm2 12/7 7x0.80mm 0.4 0.10 3.40 110 35 40 39.12
5.5mm2 10/7 7x1.00mm 0.5 0.10 4.20 120 50 55 60.56
8.0mm2 8/7 7x1.20mm 0.8 0.13 5.46 120 65 75 91.95
14mm2 6/7 7x1.60mm 0.8 0.13 6.66 100 95 105 151.77
22mm2 4/7 7x2.00mm 1.0 0.15 8.30 100 130 140 236.65
30mm2 2/7 7x2.30mm 1.0 0.15 9.20 100 160 170 306.50
38mm2 1-19 19x1.60mm 1.3 0.18 10.96 100 185 195 409.82
50mm2 1/0-19 19x1.80mm 1.3 0.18 11.96 100 220 235 509.05
60mm2 2/0-19 19x2.00mm 1.3 0.18 12.96 80 250 260 618.96
80mm2 3/0-19 19x2.30mm 1.3 0.18 14.96 80 300 320 804.44
100mm2 4/0-19 19x2.60mm 1.3 0.18 15.96 80 355 370 1013.94
125mm2 250MCM 37x2.10mm 1.6 0.18 18.26 80 400 420 1296.37
150mm2 300MCM 37x2.30mm 1.6 0.20 19.7 80 440 475 1542.02
  350MCM 37x2.47mm 1.6 0.20 20.90 60 505 523 1783.07
200mm2 400MCM 37x2.60mm 1.6 0.20 21.80 60 540 570 1946.72
  500MCM 37x2.95mm 1.6 0.20 24.25 60 620 655 2486.02
250mm2 500MCM 61x2.30mm 1.6 0.20 24.30 60 620 655 2437.34
  600MCM 61x2.52mm 1.8 0.23 26.76 60 690 710 2995.93
325mm2 650MCM 61x2.60mm 1.8 0.23 27.46 60 720 770 3191.58
  750MCM 61x2.82mm 1.8 0.23 29.36 60 785 820 3719.63
400mm2 800MCM 61x2.90mm 1.8 0.23 30.16 60 810 875 3927.55
500mm2 1000MCM 61x3.20mm 1.8 0.23 32.86 60 930 995 4750.91