URD Cable Single Conductor Aluminum Underground Direct Burial Cable 600V

URD Cable Single Conductor Aluminum Underground Direct Burial Cable 600V

Conductor: 1350-H19 series of compressed aluminum conductors

Insulation : Black resistant cross-linked polyethylene (XLP) insulation

Voltage: 600V

Email: manager@hdcable.com.cn

URD Cable Single Conductor Application

Single-conductor URD Wire is an XLPE-insulated conductor for utility underground applications, including direct burial, or for installation in electrical ducts or raceways. Single-conductor URD is permitted for 600-volt applications. Suitable for NEC applications when used as USE-2 per UL 854 and NEC 310.104(A). Suitable for use in wet or dry locations not exceeding 90°C for normal operation, 130°C for emergency overloads not to exceed 100 hours within 12 consecutive months.

Configuration


Black phase insulated conductors cabled with neutral. Neutral will be marked with yellow striping or yellow jacket.

URD Cable Single Conductor Standards:

ICEA S-105-692: 600V Single layer thermoset insulated utility underground distribution cable

UL854: Service Entrance Cables

RUS accepted

CONSTRUCTION :

 Conductors:

Class B compressed concentric lay stranded 1350 aluminum alloy per ASTM B231 or AA-8000 aluminum alloy per ASTM B800 & B801.
Insulation:
Phase conductors in black thermoset cross-linked polyethylene (XLPE). Neutral conductor in black thermoset cross-linked polyethylene (XLPE) identified by yellow striping or full yellow jacket.
Features :
Individual cables are UL Listed as USE-2

RUS accepted

Temperature rating of 90˚C dry, wet, and direct burial

Heat, ozone, oil, and chemical resistant

Tear and abrasion resistant
 
PARAMETER :

URD Cable Single Conductor 

Code Name

Size

Stranding

Insulation
Thickness

Nominal
Diameter

Approx.
Net Weight

Ampacity NEC1

Ampacity ICEA*

Inches

mm

Inches

mm

lb / kft.

kg/km

60°C

75°C

90°C

Direct Buried2

Pole Riser Conduit3

SINGLE CONDUCTOR 600V SECONDARY URD

Cornell

8

7

0.06

1.52

0.26

6.6

34

51

40

44

49

74

36

Princeton

6

7

0.06

1.52

0.3

7.6

47

70

46

56

59

96

47

Mercer

4

7

0.06

1.52

0.35

8.9

67

100

63

72

81

117

60

Clemson

2

7

0.06

1.52

0.41

10.4

97

144

86

100

108

154

82

Kenyon

1

19

0.08

2.03

0.49

12.4

128

190

98

111

124

171

97

Harvard

1/0

19

0.08

2.03

0.52

13.2

154

229

115

133

146

193

112

Yale

2/0

19

0.08

2.03

0.57

14.5

186

277

132

150

162

221

132

Tufts

3/0

19

0.08

2.03

0.62

15.7

225

335

150

172

189

253

155

Beloit

4/0

19

0.08

2.03

0.68

17.3

274

408

173

200

221

290

185

Hofstra

250

37

0.095

2.41

0.75

19.1

329

490

196

228

248

317

199

Gonzaga

300

37

0.095

2.41

0.81

20.6

385

573

224

255

281

349

223

Rutgers

350

37

0.095

2.41

0.85

21.6

439

653

242

278

302

381

248

Dartmouth

400

37

0.095

2.41

0.9

22.9

493

734

259

300

329

410

272

Brown

450

37

0.095

2.41

0.94

23.9

547

814

---

---

---

439

295

Emory

500

37

0.095

2.41

0.98

24.9

601

894

299

344

378

464

318

Duke

600

61

0.11

2.79

1.09

27.7

725

1079

328

377

416

514

355

Furman

700

61

0.11

2.79

1.16

29.5

830

1235

362

416

459

549

386

Sewanee

750

61

0.11

2.79

1.19

30.2

883

1314

368

427

470

567

403

Fordham

1000

61

0.11

2.79

1.34

34

1144

1702

431

494

540

665

492