Send message
SEND
RESET
+86 371 60975619
manager@hdcable.com.cn
+8613290961076
X1AV Cable

Power Cable 0.6/1 kV Aluminium Tape Armoured Single Core Copper Cables

Voltage Rating: 600/1000 Volts

Conductor: Copper conductor

Insulation: Cross-linked polyethylene (XLPE)

Out sheath: PVC

Armour: Aluminium Tape

Email: manager@hdcable.com.cn

X1AV Cable Application

These X1AV Armored cables for power distribution. Suitable for outdoor fixed installations when it is necessary to protect the cable against mechanical aggression or against rodent’s threat, impact or crushing. Can be installed in ducts, or directly buried. Excellent mechanical protection during laying, installation and service.


X1AV Cable Standard:

IEC 60502-1
Flame Retardant according to IEC 60332-1 IEC 60332-1-2
CONSTRUCTION :

X1AV Cable Construction

 

Conductor: 1.5mm² to 4mm²: Class 1 solid copper conductor
                   6mm² and above: Class 2 stranded copper conductor 
                  Class 2 stranded conductor available for these sizes on request

Insulation: Cross-linked polyethylene (XLPE) insulation type XLPE according to IEC 60502-1.

Armour bedding: Black extruded PVC separation sheath.

Armour: Double aluminium tape armour. Aluminium armour is used in single-core cables to avoid parasite currents that may overheat the cable. 

Outer sheath: Flexible PVC outer sheath, Black colour.

 
  
CHARACTERISTICS :

X1AV Cable Characteristics

Electrical performance: Low voltage 0,6/1kV.
Thermal performance:
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance:
Flame non-propagation according to EN 60332-1 and IEC 60332-1.
Reduced halogen emission. Chlorine <15%.
Reaction to fire CPR: Eca, according to EN 50575.
Mechanical performance:
Minimum bending radius: x5 cable diameter.
Impact resistance: AG2 Medium severity.
Environmental performance
Chemical & Oil resistance: Good.
UV Resistant: UNE 211605.
Installation conditions
Open Air.
Buried.
In conduit.
 
Other
Meter by meter marking. 
PARAMETER :
X1AV Cable Parameter 
Nominal cross sectional area Insulation thickness Non-magnetic steel tape thickness  Sheath thickness Approximate outer diameter Approx.
weight
mm2 mm mm mm mm kg/km
1X10 0.7 0.2 1.8 11.8 244.0
1X16 0.7 0.2 1.8 12.9 318.0
1X25 0.9 0.2 1.8 14.6 430.0
1X35 0.9 0.2 1.8 15.2 533.0
1X50 1.0 0.2 1.8 16.7 668.0
1X70 1.1 0.2 1.8 18.5 893.0
1X95 1.1 0.2 1.8 20.1 1157.0
1X120 1.2 0.2 1.8 21.7 1410.0
1X150 1.4 0.2 1.8 23.7 1705.0
1X185 1.6 0.2 1.8 25.7 2082.0
1X240 1.7 0.2 1.8 28.0 2652.0
1X300 1.8 0.2 1.9 31.0 3259.0
1X400 2.0 0.2 2.0 35.0 4135.0