YY Control Cable-PVC Insulated Flexible Control Cable VDE 0250

CU PVC PVC Control Cable

Voltage Rating: 300/500V

Conductor: soft annealed copper

Insulation: PVC

Sheath: PVC

Email: manager@hdcable.com.cn

YY Control Cable Application

YY Control Cable is used as a control cable on conveyors, assembly and production lines. It is generally used indoors as an interconnecting cable in signal and control equipment.

These cables are not UV resistant but can be used outdoors if adequately protected against direct sunlight in trunking etc.

YY Control Cable Standard

Generally to BS6500 and VDE0250
CONSTRUCTION :

YY Control Cable Structure

Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5
Core insulation of special PVC compound type Z 7225
Core identification to DIN VDE 0293 black cores with continuous white numbering
GN-YE conductor, 3 cores and above in the outer layer
Cores stranded in layers with optimal lay length
Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1
Sheath colour: grey (RAL 7001)
kvv cable structure
TECHNICAL DATA :

YY Control Cable Technical Data

Voltage Rating: 300/500 Volts

Temperature limits:

Static: -20°C to +80°C
Flexing: -5°C to +70°C
Minimum Bending Radius: As Per Manufacturers Datasheet
Should not be installed at temperatures below -5°C 

PARAMETER :

2 Core YY Control Cable Specifications

Part No. No.
Cores
Conduct or
Cross Secton
Area (mm²)
Cable Cross
Secton Area
(mm²)
Overall
Diameter
(mm)
Gland
Size
Cleat
Size
Nominal
Weight
(kg/km)
Resistance of
Copper Conductor
(Ω/Km) at 200C
2C.75YY 2 0.75 27.32 5.9 20S 3 50 26
2C1.0YY 2 1 30.17 6.2 20S 3 55 19.5
2C1.5YY 2 1.5 36.29 6.8 20S 3 80 13.3
2C2.5YY 2 2.5 55.38 8.4 20S 3 135 7.98
2C4.0YY 2 4 84.9 10.4 20S 4 197 4.95
2C6.0YY 2 6 113.04 12 20 5 225 3.3
2C10YY 2 10 171.94 14.8 25 6 460 1.91

3 Core YY Control Cable Specifications

Part No. No.
Cores
Conduct or
Cross Secton
Area (mm²)
Cable Cross
Secton Area
(mm²)
Overall
Diameter
(mm)
Gland
Size
Cleat
Size
Nominal
Weight
(kg/km)
Resistance of
Copper Conductor
(Ω/Km) at 200C
3C.75YY 3 0.75 30.17 6.2 20S 3 60 26
3C1.0YY 3 1 33.16 6.5 20S 3 70 19.5
3C1.5YY 3 1.5 40.69 7.2 20S 3 95 13.3
3C2.5YY 3 2.5 62.17 8.9 20S 4 165 7.98
3C4.0YY 3 4 98.47 11.2 20 5 250 4.95
3C6.0YY 3 6 128.61 12.8 20 6 305 3.3
3C10YY 3 10 195.96 15.8 25 7 590 1.91
3C16YY 3 16 265.76 18.4 32 8 800 1.21
3C25YY 3 25 633.14 28.4 40 12 1400 0.78
3C35YY 3 35 798.82 31.9 40 14 1840 0.554
3C50YY 3 50 1115.71 37.7 50 16 2550 0.38

4 Core YY Control Cable Specifications

Part No. No.
Cores
Conduct or
Cross Secton
Area (mm²)
Cable Cross
Secton Area
(mm²)
Overall
Diameter
(mm)
Gland
Size
Cleat
Size
Nominal
Weight
(kg/km)
Resistance of
Copper Conductor
(Ω/Km) at 200C
4C.75YY 4 0.75 35.23 6.7 20S 3 70 26
4C1.0YY 4 1 39.57 7.1 20S 3 85 19.5
4C1.5YY 4 1.5 51.5 8.1 20S 3 120 13.3
4C2.5YY 4 2.5 73.86 9.7 20S 4 200 7.98
4C4.0YY 4 4 130.63 12.9 20 6 300 4.95
4C6.0YY 4 6 160.52 14.3 25 6 390 3.3
4C10YY 4 10 243.16 17.6 25 7 720 1.91
4C16YY 4 16 329.89 20.5 32 9 1000 1.21
4C25YY 4 25 778.91 31.5 40 14 1800 0.78
4C35YY 4 35 978.18 35.3 50 14 2380 0.554
4C50YY 4 50 1365.02 41.7 63 18 3290 0.386

5 Core YY Control Cable Specifications

Part No. No.
Cores
Conduct or
Cross Secton
Area (mm²)
Cable Cross
Secton Area
(mm²)
Overall
Diameter
(mm)
Gland
Size
Cleat
Size
Nominal
Weight
(kg/km)
Resistance of
Copper Conductor
(Ω/Km) at 200C
5C.75YY 5 0.75 42.98 7.4 20S 3 88.5 26
5C1.0YY 5 1 46.54 7.7 20S 3 100 19.5
5C1.5YY 5 1.5 63.58 9 20S 4 150 13.3
5C2.5YY 5 2.5 91.56 10.8 20 5 255 7.98
5C4.0YY 5 4 147.33 13.7 20 6 355 4.95
5C6.0YY 5 6 191.03 15.6 25 7 470 3.3
5C10YY 5 10 298.49 19.5 32 7 865 1.91
5C16YY 5 16 404.5 22.7 40 9 1250 1.21
5C25YY 5 25 945.21 34.7 50 14 2220 0.78
5C35YY 5 35 1187.86 38.9 63 16 2790 0.554
 